Toxics Use Reduction Case Study
VOC and Freon Reduction At Galileo Electro-Optics Corporation
Summary
Galileo Electro-Optics Corporation of Sturbridge, Massachusetts, implemented chemical substitution in
its production and quality inspection areas to reduce volatile organic compound (VOC) emissions. The
changes which cost less than $ 1,000 have reduced trichloroethylene (TCE) purchases, usage and
emissions in the production operation by more than 95%. A Galileo-designed reclamation system
recycles Freon in-process. This has reduced Freon purchases by 72% and cut emissions by nearly 60%
from 1988 levels. In quality inspections, the annual use and emission of 560 pounds of Freon has been
eliminated, saving the firm $2,700 each year.
Background
The Galileo Electro-Optics Corporation, which employs 250 people, manufactures fiber optic plates. In
the typical production sequence, plates are mounted to fixtures using wax prior to cutting, polishing or
grinding. TCE was then used to remove the wax.
In a quality control inspection operation, a Freon-based aerosol was used to blow dust and debris off the
part. (It is necessary to thoroughly remove the contaminants in order to obtain accuracy in inspection.)
As part of the manufacturing process, glass fibers are placed in molds to form fused blocks of fibers.
These blocks act to transfer images with a high degree of clarity, such as in photocopier machines. Prior
to molding, the fibers are cleaned in a two-part vapor degreaser which uses Freon. First, a Freon-based
soap solution washes the fibers. Following the wash, the fibers are rinsed in a Freon-based solvent then
dried and assembled into the molds. It is vital that the fibers be free of contamination, which creates
cracks in the fibers, spoiling the resolution of the image. Also, the cleaning solvent itself must readily
evaporate from the fibers; otherwise, the blocks explode when subjected to high temperatures in a further
processing step. Currently, only Freon meets the evaporation and cleaning needs of Galileo.
Toxic Use Reduction
After attending seminars given by OTA and DEP on toxics use reduction, Galileo formed a Toxics Use
Reduction Task Force to investigate the potential for removing highly toxic chemicals from the work
area. In addition to purchase and disposal costs the use of such chemicals impacts on the cost of
ventilation needed to insure worker safety.
As part of the planning process, all employees were requested to submit ideas and suggestions to the task
force. These ideas were incorporated into reduction plans submitted by the task force. Vendors were
consulted concerning waxes and alloys which could be removed without the use of TCE. Galileo's long-term plan is to eliminate Freon use in cleaning. In the meantime, Galileo is focusing on eliminating the
cleaning steps in the manufacture of their product. Parts will be manufactured clean rather than cleaned
after being made.
Toxics Use Reduction Modifications
The substitutions required no new equipment modifications or worker training. TCE substitution
required approximately 20 hours of in-house testing by production engineers and product scientists. The
new wax and alloy have low melting temperatures. These new materials hold the piece during
machining, yet can be melted for easy removal. This allows Galileo to use water heated to 175 F to
remove the material. Some material requires acetone for removal (Galileo is researching aqueous
alternatives.)
By installing prefiltered air hoses and nozzles, Galileo has been able to substitute dry pure nitrogen for
the Freon used in quality inspections. The nitrogen is supplied by cylinders in another area of the
facility. Each 1000 pound cylinder lasts approximately 30 days.
Galileo designed and installed an integral pumping system, still and holding tanks to reclaim and permit
re-use of the Freon used in cleaning. A pilot system was tested, using small quantities of material to
prove that the reclamation method did not affect product quality. The material within the degreaser is
tested regularly before being removed for reclamation. Galileo actively maintains the Freon so that the
material lasts longer and changes can be made less frequently.
Results
Reductions Achieved: TCE use was cut from 1849 pounds per year to 100 pounds per year in the small
and large glass mounting area. In quality inspection, Freon use has been eliminated. Overall, Freon
emissions have been reduced from 157,591 pounds in 1988 to 33,673 pounds in 1992.
Economics: The TCE substitution took 4 hours to research and 20 hours to test. The switch cost less than
$1000 to implement. The substitution eliminated the need for improved safety and ventilation
equipment, which would have cost a minimum of $10,000. Galileo's use of TCE is now well below
reporting thresholds for the federal and state governments. By disposing of less contaminated TCE,
Galileo saves $10,600 yearly.
The substitution of nitrogen for Freon took 5 hours of planning and design, and 26 hours of installation
time. The project cost a total of $3,000 and has saved $2,700 yearly. This change has permitted Galileo
to eliminate the use and emission of more than 560 pounds of Freon each year. In light of the fact that
the price of Freon and TCE rise every year, the savings are likely to increase over time.
Galileo spent about half a year with a model unit making alterations on a trial unit. An additional year
was spent automating the unit and phasing it in facility-wide. Approximately 200 hours were spent on
installation and set-up of the production unit. Labor costs were approximately $3,000 and equipment
costs were $12,000. The 110 drums of Freon saved led to cost reductions of $110,000 yearly. Galileo
then learned that Freon will increase to $2000 per drum further increasing purchase savings.
This case study is one in a series prepared by the Office of Technical Assistance (OTA), a branch of the
Massachusetts Executive Office of Environmental Affairs. OTA's mission is to assist industry in reducing
the use of toxic chemicals and/or the generation of toxic manufacturing byproducts. Mention of any
particular equipment or proprietary technology does not represent an endorsement of these products by
the Commonwealth of Massachusetts. This information is available in alternate formats upon request.
OTA's confidential, non-regulatory services are available at no charge to Massachusetts businesses and
institutions that use toxics. For further information about this or other case studies, or about OTA's
technical assistance services, contact: Office of Technical Assistance, 251 Causeway St., Boston, Massachusetts 02114. Phone #(617) 626-1060. Fax #(617) 626-1095.
Website: http://www.state.ma.us/ota.
|