Section 258.51 GROUND-WATER MONITORING SYSTEMS

Previous Section | 258 Contents | Next Section

Performance Standard:

Monitoring System:

258.51(a) A ground-water monitoring system must be installed that consists of a sufficient number of wells, installed at appropriate locations and depths, to yield ground-water samples from the uppermost aquifer (as defined in sec. 258.2) that:

258.51(a)(1) Represent the quality of background ground water that has not been affected by leakage from a unit. A determination of background quality may include sampling of wells that are not hydraulically upgradient of the waste management area where:

258.51(a)(1)(i) Hydrogeologic conditions do not allow the owner or operator to determine what wells are hydraulically upgradient; or

258.51(a)(1)(ii) Sampling at other wells will provide an indication of background ground-water quality that is as representative or more representative than that provided by the upgradient wells; and

258.51(a)(2) Represent the quality of ground water passing the relevant point of compliance specified by Director of an approved State under sec. 258.40(d) or at the waste management unit boundary in unapproved States. The downgradient monitoring system must be installed at the relevant point of compliance specified by the Director of an approved State under sec. 258.40(d) or at the waste management unit boundary in unapproved States that ensures detection of ground-water contamination in the uppermost aquifer. When physical obstacles preclude installation of ground-water monitoring wells at the relevant point of compliance at existing units, the down-gradient monitoring system may be installed at the closest practicable distance hydraulically down-gradient from the relevant point of compliance specified by the Director of an approved State under sec. 258.40 that ensure detection of groundwater contamination in the uppermost aquifer.

Multi-Unit System:

258.51(b) The Director of an approved State may approve a multi-unit ground-water monitoring system instead of separate ground-water monitoring systems for each MSWLF unit when the facility has several units, provided the multi-unit ground-water monitoring system meets the requirement of sec. 258.51(a) and will be as protective of human health and the environment as individual monitoring systems for each MSWLF unit, based on the following factors:

258.51(b)(1) Number, spacing, and orientation of the MSWLF units;

258.51(b)(2) Hydrogeologic setting;

258.51(b)(3) Site history;

258.51(b)(4) Engineering design of the MSWLF units, and

258.51(b)(5) Type of waste accepted at the MSWLF units.

Design Standard:

Wells:

258.51(c) Monitoring wells must be cased in a manner that maintains the integrity of the monitoring well bore hole. This casing must be screened or perforated and packed with gravel or sand, where necessary, to enable collection of ground-water samples. The annular space (i.e., the space between the bore hole and well casing) above the sampling depth must be sealed to prevent contamination of samples and the ground water.

Performance Standard:

258.51(c)(1) The owner or operator must notify the State Director that the design, installation, development, and decommission of any monitoring wells, piezometers and other measurement, sampling, and analytical devices documentation has been placed in the operating record; and

258.51(c)(2) The monitoring wells, piezometers, and other measurement, sampling, and analytical devices must be operated and maintained so that they perform to design specifications throughout the life of the monitoring program.

258.51(d) The number, spacing, and depths of monitoring systems shall be:

258.51(d)(1) Determined based upon site-specific technical information that must include thorough characterization of:

258.51(d)(1)(i) Aquifer thickness, ground-water flow rate, ground-water flow direction including seasonal and temporal fluctuations in ground-water flow; and

258.51(d)(1)(ii) Saturated and unsaturated geologic units and fill materials overlying the uppermost aquifer, materials comprising the uppermost aquifer, and materials comprising the confining unit defining the lower boundary of the uppermost aquifer; including, but not limited to: thicknesses, stratigraphy, lithology, hydraulic conductivities, porosities and effective porosities.

258.51(d)(2) Certified by a qualified ground-water scientist or approved by the Director of an approved State. Within 14 days of this certification, the owner or operator must notify the State Director that the certification has been placed in the operating record.

  About EPA | Other Info | State Data | State Profiles | Waste Generation | Waste Disposal | Waste Components
International Practices | Source Reduction | Recycling | Combustion | Land Disposal