Section 258.21 COVER MATERIAL REQUIREMENTS

Previous Section | 258 Contents | Next Section

Design Standard:

258.21(a) Except as provided in paragraph (b) of this section, the owners or operators of all MSWLF units must cover disposed solid waste with six inches of earthen material at the end of each operating day, or at more frequent intervals if necessary, to control disease vectors, fires, odors, blowing litter, and scavenging.

Performance Standard:

258.21(b) Alternative materials of an alternative thickness (other than at least six inches of earthen material) may be approved by the Director of an approved State if the owner or operator demonstrates that the alternative material and thickness control disease vectors, fires, odors, blowing litter, and scavenging without presenting a threat to human health and the environment.

Waiver:

258.21(c) The Director of an approved State may grant a temporary waiver from the requirement of paragraph (a) and (b) of this section if the owner or operator demonstrates that there are extreme seasonal climatic conditions that make meeting such requirements impractical.

  About EPA | Other Info | State Data | State Profiles | Waste Generation | Waste Disposal | Waste Components
International Practices | Source Reduction | Recycling | Combustion | Land Disposal

[ Top of Screen ]

 

 

Last Revised: November 14, 1997

comments: levy.steve@epamail.epa.gov

URL: www.epa.gov/epaoswer/non-hw/muncpl/factbook/internet/lanf/258t21.htm

OSW Home www.epa.gov/epaoswer/osw/index.htm

EPA Home www.epa.gov/epahome

Search the EPA Web www.epa.gov/epahome/search.html